{"id":1792,"date":"2023-04-03T13:21:34","date_gmt":"2023-04-03T04:21:34","guid":{"rendered":"http:\/\/adop-mjc-test.com\/?page_id=1509"},"modified":"2023-04-03T13:21:34","modified_gmt":"2023-04-03T04:21:34","slug":"low_current_manual_8","status":"publish","type":"page","link":"https:\/\/adop-mjc-test.com\/en\/products_service\/wafer_prober\/low_current_manual_8\/","title":{"rendered":"Manual Prober (For 8-inch wafer Low Current Measurement)"},"content":{"rendered":"<section>\n<div class=\"title--no-image\">\n<h1 class=\"inner\">Manual Prober <br \/>(For 8-inch wafer Low Current Measurement)<\/h1>\n<\/div>\n<div class=\"inner\">\n<ul class=\"breadcrumbs\">\n<li><a href=\"\/en\/\">Top<\/a><\/li>\n<li><a href=\"\/en\/products_service\/\">Products\u30fbService<\/a><\/li>\n<li><a href=\"\/en\/products_service\/wafer_prober\/\">Wafer Prober<\/a><\/li>\n<li>Manual Prober (For 8-inch wafer Low Current Measurement)<\/li>\n<li><\/li>\n<\/ul>\n<\/div>\n<section>\n<div class=\"inner product-detail__title\">\n<h2 class=\"title--hyphen show lazy\">Features<\/h2>\n<\/div>\n<section class=\"pdg-b170\">\n<div class=\"product-detail__lead\">\n<div class=\"show lazy\">\n<div class=\"product-detail__image\"><img decoding=\"async\" src=\"https:\/\/adop-mjc-test.com\/wp-content\/themes\/adop-mjc\/img\/products\/Model_708fT_image.jpg\" alt=\"\" \/><\/div>\n<div class=\"product-detail__brown\">\n<div class=\"product-detail__brown-line\">\n<h3>Model 708fT<\/h3>\n<p class=\"font20--text\">Manual Prober for 8-inch wafer<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"pdg-t120 pdg-b170 bg-gray\">\n<div class=\"inner\">\n<p class=\"wafer__catch show lazy\">Manual prober model capable of measuring fA-level low current<\/p>\n<h4 class=\"title--border-left title--border-left--wafer show lazy\"><span>Low current measurement<\/span><\/h4>\n<ul class=\"product-detail__features flex_pc flex_fw flex_jsb pdg-t40 pdg-b120\">\n<li class=\"show lazy\">\n<p><span class=\"poppins\">01<\/span>The three-layer structure with guard and shield allows measurement of fA-level low current<\/p>\n<\/li>\n<li class=\"show lazy\">\n<p><span class=\"poppins\">02<\/span>Despite the simple structure, this model allows low-noise, high-accuracy measurement<\/p>\n<\/li>\n<\/ul>\n<h4 class=\"title--border-left title--border-left--wafer show lazy\"><span>Easy operation<\/span><\/h4>\n<ul class=\"product-detail__features flex_pc flex_fw flex_jsb pdg-t40 pdg-b120\">\n<li class=\"product-detail__feature100 show lazy\">\n<div>\n<p><span class=\"poppins\">01<\/span>Air bearing stage for easy one-handed operation<\/p>\n<p class=\"font-normal\">Allows stage positioning within a short time, which improves measurement efficiency.<\/p>\n<\/div>\n<\/li>\n<\/ul>\n<h4 class=\"title--border-left title--border-left--wafer show lazy\"><span>Safety design<\/span><\/h4>\n<ul class=\"product-detail__features flex_pc flex_fw flex_jsb pdg-t40 pdg-b120\">\n<li class=\"product-detail__feature100 show lazy\">\n<div>\n<p><span class=\"poppins\">01<\/span>Safety lock mechanism to prevent damage to devices and probes caused by improper contact operation<\/p>\n<p class=\"font-normal\">Reduces wasteful remaking of devices, remeasurement, and probe maintenance.<\/p>\n<\/div>\n<\/li>\n<\/ul>\n<h4 class=\"title--border-left title--border-left--wafer show lazy\"><span>Various customization options available<\/span><\/h4>\n<div class=\"pdg-t40 pdg-b120 show lazy\">\n<ul class=\"product-detail__feature-list list-disc\">\n<li>Can be equipped with hot chuck (+40\u2103 to +200\u2103) for evaluation of temperature-dependent properties<\/li>\n<li>Customizable according to intended use<\/li>\n<\/ul>\n<\/div>\n<h4 class=\"title--border-left title--border-left--wafer show lazy\"><span>Specifications: Model 708fT Manual Prober (for 8-inch wafer Low Current Measurement)<\/span><\/h4>\n<div class=\"pdg-t40 show lazy\">\n<div class=\"wafer__scroll\">\n<table class=\"table--line-th-black table--line-th-black--wafer\">\n<tbody>\n<tr>\n<th class=\"no-line\">Maximum wafer size<\/th>\n<td>\u03c6200mm<\/td>\n<\/tr>\n<tr>\n<th class=\"no-line\">Stage travel <br \/>(rough adjustment)<\/th>\n<td>X: 220mm\u2003Y\uff1a270mm<\/td>\n<\/tr>\n<tr>\n<th class=\"no-line\">Sub-stage travel <br \/>(fine adjustment)<\/th>\n<td>X: 10mm\u2003Y: 10mm<\/td>\n<\/tr>\n<tr>\n<th class=\"no-line\">Z stroke<\/th>\n<td>0 \/ 0.3 \/ 3.5mm+3mm<\/td>\n<\/tr>\n<tr>\n<th class=\"no-line\">\u0398 travel<\/th>\n<td>\u00b15\u00b0<\/td>\n<\/tr>\n<tr>\n<th class=\"no-line\">External dimensions <br \/>(WxDxH)<\/th>\n<td>897mm\u00d7863mm\u00d7400mm (excluding options)<\/td>\n<\/tr>\n<tr>\n<th class=\"no-line\">System weight<\/th>\n<td>120kg (excluding options)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<\/section>\n<section>\n  <div class=\"inner\">\n    <h2 class=\"title--hyphen pdg-b70 show lazy\">List of Wafer Prober Products<\/h2>\n    <ul class=\"product-link2 flex_pc flex_fw flex_jsb pdg-b120 font20--text\">\n      <li class=\"show lazy\">\n        <a href=\"\/en\/products_service\/wafer_prober\/excelyze_manual_12\/\" class=\"flex\">\n          <div class=\"product-link2__image\"><img decoding=\"async\" src=\"https:\/\/adop-mjc-test.com\/wp-content\/themes\/adop-mjc\/img\/products\/wafer_prober12.jpg?v=20251113\" alt=\"\"><\/div>\n          <p class=\"product-link2__title\" style=\"line-height: 1.3em;\">Excelyze Manual Prober <br><span style=\"font-size: 0.8em; line-height: 1.3em;\">(for 12-inch wafer Low Current Measurement)<\/span><\/p>\n        <\/a>\n      <\/li>\n      <li class=\"show lazy\">\n        <a href=\"\/en\/products_service\/wafer_prober\/low_current_semi_8\/\" class=\"flex\">\n          <div class=\"product-link2__image\"><img decoding=\"async\" src=\"https:\/\/adop-mjc-test.com\/wp-content\/themes\/adop-mjc\/img\/products\/wafer_prober1.jpg\" alt=\"\"><\/div>\n          <p class=\"product-link2__title\" style=\"line-height: 1.3em;\">Semi-Automatic Prober <br><span style=\"font-size: 0.8em; line-height: 1.3em;\">(for 8-inch wafer Low Current Measurement)<\/span><\/p>\n        <\/a>\n      <\/li>\n      <li class=\"show lazy\">\n        <a href=\"\/en\/products_service\/wafer_prober\/low_current_manual_8\/\" class=\"flex\">\n          <div class=\"product-link2__image\"><img decoding=\"async\" src=\"https:\/\/adop-mjc-test.com\/wp-content\/themes\/adop-mjc\/img\/products\/wafer_prober4.jpg\" alt=\"\"><\/div>\n          <p class=\"product-link2__title\" style=\"line-height: 1.3em;\">Manual Prober <br><span style=\"font-size: 0.8em; line-height: 1.3em;\">(for 8-inch wafer Low Current Measurement)<\/span><\/p>\n        <\/a>\n      <\/li>\n      <li class=\"show lazy\">\n        <a href=\"\/en\/products_service\/wafer_prober\/analysis_manual_6_8\/\" class=\"flex\">\n          <div class=\"product-link2__image\"><img decoding=\"async\" src=\"https:\/\/adop-mjc-test.com\/wp-content\/themes\/adop-mjc\/img\/products\/wafer_prober3.jpg\" alt=\"\"><\/div>\n          <p class=\"product-link2__title\" style=\"line-height: 1.3em;\">Manual Prober <br><span style=\"font-size: 0.8em; line-height: 1.3em;\">(for 6-inch wafer\/8-inch wafer)<\/span><\/p>\n        <\/a>\n      <\/li>\n      <li class=\"show lazy\">\n        <a href=\"\/en\/products_service\/wafer_prober\/analysis_manual_12\/\" class=\"flex\">\n          <div class=\"product-link2__image\"><img decoding=\"async\" src=\"https:\/\/adop-mjc-test.com\/wp-content\/themes\/adop-mjc\/img\/products\/wafer_prober2.jpg\" alt=\"\"><\/div>\n          <p class=\"product-link2__title\" style=\"line-height: 1.3em;\">Manual Prober <br><span style=\"font-size: 0.8em; line-height: 1.3em;\">(for 12-inch wafer)<\/span><\/p>\n        <\/a>\n      <\/li>\n      <li class=\"show lazy\">\n        <a href=\"\/en\/products_service\/wafer_prober\/personal_manual_2_4\/\" class=\"flex\">\n          <div class=\"product-link2__image\"><img decoding=\"async\" src=\"https:\/\/adop-mjc-test.com\/wp-content\/themes\/adop-mjc\/img\/products\/wafer_prober5.jpg\" alt=\"\"><\/div>\n          <p class=\"product-link2__title\" style=\"line-height: 1.3em;\">Personal Manual Prober <br><span style=\"font-size: 0.8em; line-height: 1.3em;\">(for 2-inch wafer\/4-inch wafer)<\/span><\/p>\n        <\/a>\n      <\/li>\n    <\/ul>\n\n    <h2 class=\"title--hyphen pdg-b70 show lazy\">Accessories \/ Options and Maintenance Parts<\/h2>\n    <ul class=\"product-link2 flex_pc flex_fw flex_jsb font20--text\">\n      <li class=\"show lazy\">\n        <a href=\"\/en\/products_service\/wafer_prober\/probe_accessory\/\" class=\"flex\">\n          <div class=\"product-link2__image\"><img decoding=\"async\" src=\"https:\/\/adop-mjc-test.com\/wp-content\/themes\/adop-mjc\/img\/products\/wafer_prober10.jpg\" alt=\"\"><\/div>\n          <p class=\"product-link2__title\">Accessories \/ <br>Options and Maintenance Parts<\/p>\n        <\/a>\n      <\/li>\n    <\/ul>\n  <\/div>\n<\/section>\n\n<p class=\"btn-wrapper--center pdg-tb170 show lazy\"><a href=\"\/en\/products_service\/wafer_prober\/\" class=\"btn--dark-brown-back btn--wide\">Back to Wafer Prober<\/a><\/p>\n<section class=\"common-contact common-contact--en\">\n  <div class=\"inner flex_pc flex_ac show lazy\">\n    <h2 class=\"common-contact__title\">Contact Us<\/h2>\n    <p class=\"common-contact__text font-sp14\">Contact us for any support or queries you may have about our products.<\/p>\n    <p class=\"common-contact__link\"><a href=\"https:\/\/adop-mjc-test.com\/en\/contact-form?type=product\" class=\"btn--transparent poppins\">CONTACT<\/a><\/p>\n  <\/div>\n<\/section> \n<script src=\"https:\/\/adop-mjc-test.com\/wp-content\/themes\/adop-mjc\/js\/swiper-bundle.min.js\"><\/script>\n<script>\n  \/\/ \u95a2\u9023\u60c5\u5831\u30b9\u30e9\u30a4\u30c0\u30fc\n  const relateSwiper = new Swiper ('.relate__swiper', {\n    loop: true,\n    centeredSlides: true,\n    slidesPerView: 1.5,\n    spaceBetween: 20,\n    breakpoints: {\n      500: {\n        loop: true,\n        centeredSlides: false,\n        slidesPerView: 2.5,\n        spaceBetween: 20,\n      },\n      900: {\n        loop: false,\n        centeredSlides: false,\n        slidesPerView: 3,\n        spaceBetween: 30,\n      },\n      1250: {\n        loop: false,\n        centeredSlides: false,\n        slidesPerView: 3,\n        spaceBetween: 50,\n      }\n    },\n  });\n<\/script><\/section>","protected":false},"excerpt":{"rendered":"Here you will find information on the Wafer Prober product &#8220;Manual Prober (for measuring 8-inch micro current)&#8221; provided by MJC.","protected":false},"author":14,"featured_media":0,"parent":1790,"menu_order":229,"comment_status":"closed","ping_status":"closed","template":"page-products-wafer-low-manual-8-en.php","meta":{"_locale":"en_US","_original_post":"https:\/\/mjc-release.xyz\/?p=663","footnotes":"","_expiration-date-status":"","_expiration-date":0,"_expiration-date-type":"","_expiration-date-categories":[],"_expiration-date-options":[]},"class_list":["post-1792","page","type-page","status-publish","hentry","en-US"],"_links":{"self":[{"href":"https:\/\/adop-mjc-test.com\/wp-json\/wp\/v2\/pages\/1792","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/adop-mjc-test.com\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/adop-mjc-test.com\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/adop-mjc-test.com\/wp-json\/wp\/v2\/users\/14"}],"replies":[{"embeddable":true,"href":"https:\/\/adop-mjc-test.com\/wp-json\/wp\/v2\/comments?post=1792"}],"version-history":[{"count":0,"href":"https:\/\/adop-mjc-test.com\/wp-json\/wp\/v2\/pages\/1792\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/adop-mjc-test.com\/wp-json\/wp\/v2\/pages\/1790"}],"wp:attachment":[{"href":"https:\/\/adop-mjc-test.com\/wp-json\/wp\/v2\/media?parent=1792"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}